Skip to content
Puede usar nuestro buscador para encontrar información sobre los productos y soluciones de InterSystems, las oportunidades de desarrollo profesional, los casos de uso, novedades y mucho más.

Alert: Possible Data Integrity Issues with Online Backup of Large Databases

May 20, 2020 – Alert: Possible Data Integrity Issues with Online Backup of Large Databases

InterSystems has corrected two defects that affect online backup of very large databases. Backups taken via external methods, such as snapshots or direct file copies, are not affected. These defects exist in all released versions of all InterSystems products.

The first defect only affects databases with more than 231 blocks. It results in a degraded database after restoring from an online backup. For example, databases that have a block size of 8 KB (the default) are only affected if they are larger than 16 TB. The correction for this defect is identified as RJF437.

The second defect affects databases that have a block size of 8 KB and that are larger than ~29 TB. With this defect, the online backup fails due to an inaccurate <DATABASE> error; this results in a backup that cannot be restored. The correction for this defect is identified as RJF438. Note that this defect also affects databases that have block sizes smaller than 8 KB.

The corrections for these defects will be included in all future product releases. They are also available by requesting an Ad hoc distribution from the WRC.

If you have any questions regarding this alert, please contact the Worldwide Response Center.

Latest Alerts & Advisories

Jul 23 2025
InterSystems IRIS 2025.2 introduces the IRISSECURITY database, the new home for security data. Unlike IRISSYS, the previous home for security data, IRISSECURITY can be encrypted, which secures your sensitive data at rest. In a future version, IRISSECURITY will be mirrorable.
Jul 23 2025
InterSystems is pleased to announce the General Availability (GA) of the 2025.2 release of InterSystems IRIS® data platform. This is a Continuous Delivery (CD) release. Please note that the GA versions of InterSystems IRIS for Health™ and HealthShare® Health Connect™ 2025.2 are currently withheld due to mirroring limitations introduced by security updates (details below).
Jun 10 2025
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements DP-439649 Products:
May 20 2025
This issue affects all versions of HealthShare®:
May 20 2025
This problem affects the following products: