Skip to content
Puede usar nuestro buscador para encontrar información sobre los productos y soluciones de InterSystems, las oportunidades de desarrollo profesional, los casos de uso, novedades y mucho más.

Alert: Database Corruption with Multi-Volume Databases after Truncation

InterSystems has corrected a defect that can cause database corruption or <DISKHARD> errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.

The defect exists in the following products and any InterSystems offerings based on them:

  • InterSystems IRIS® – 2024.1, 2024.1.1, and 2024.2
  • InterSystems IRIS® for Health – 2024.1, 2024.1.1, and 2024.2
  • HealthShare® Health Connect – 2024.1, 2024.1.1, and 2024.2

No HealthShare Solutions products are affected by this defect.

Although InterSystems has received no reports from customers due to this defect, we recommend the following temporary mitigation to avoid the problem:

  • Do not truncate multi-volume databases.
  • Do not create a new volume for a single- or multi-volume database that you have truncated since the last time the database was mounted. To disable automatic creation, set the configuration parameter New Volume Threshold = 0.  Note that setting this parameter does not prevent manual creation of new volumes.

The correction for this defect is identified as DP-433375. It will be included in all future versions and is also available via Ad-hoc distribution.

If you have any questions regarding this alert, please contact the Worldwide Response Center.

Latest Alerts & Advisories

Oct 21 2026
Advisory ID Products Affected Risk Category & Score Explicit Requirements DP-456155 All existing InterSystems interoperability products and solutions that use browser-based XSLT, including:
Oct 08 2026
We’re excited to introduce the new InterSystems Software Distribution Platform, available beginning October 8 at downloads.intersystems.com.
Sep 11 2026
This problem affects all versions of Unified Care Record and Information Exchange prior to 2026.2.
Jul 22 2026
The 2026.2 release of InterSystems IRIS® data platform, InterSystems IRIS® for Health™, and HealthShare® Health Connect is now Generally Available (GA). This is a Continuous Delivery (CD) release.
Jul 22 2026
There are 6 alerts in the HealthShare HS2026-01 Alert communication. Alert Summaries are shown in the table below. Alert details are contained in the PDF document: HS-2026-01-Alert-Document
Jul 22 2026
There are 4 alerts in the HealthShare HS2026-02 Alert communication. Alert Summaries are shown in the table below. Alert details are contained in the PDF document: HS-2026-02-Alert-Document
Jul 22 2026
This problem affects the following products: