This problem affects the following products:

  • Upgrades to HealthShare Unified Care Record® (Registry instance), versions:

2023.1 • 2023.2 • 2024.1

Requirements:

  • Customers using Federated SSO who upgrade a Registry to an affected version

A defect has been corrected in HealthShare 2024.2 that had affected upgrades to HealthShare 2023.1, 2023.2, or 2024.1 In those versions, an upgrade step inadvertently triggers OAuth 2.0 token revocation requests for all active tokens on the system.Since the system is currently being upgraded, the requests all fail serially and sequentially. On an active system with more than one hundred (100) active tokens, the unnecessary delay may increase downtime by an hour or more.

The HS.Util.Installer.HSSYS-1.log will provide an indication to administrators that the issue is occurring if they see the following entry for more than a minute:

HS.Util.Installer.Upgrade.Loader:Upgrade
HS.Util.Installer.Upgrade.V25:CoreStep3 started

Further indication of the issue can be found in the messages.log which may report a long-running transaction if token revocation runs for more than 10 minutes:

1 [Utility.Event] [SYSTEM MONITOR] TransOpenSecs Warning: Transactions open longer than 10 minutes. Process id24940 (only top 5 shown)

A mitigation strategy has been added to the HealthShare 2023.1, 2023.2, and 2024.1 upgrade documentation that explains how to Delete OAuth Tokens from the Registry immediately before performing the upgrade.

This issue is corrected in version 2024.2 and later.

RELATED TOPICS

Latest Alerts & Advisories

May 20, 2025
This issue affects all versions of HealthShare®:
May 20, 2025
This problem affects the following products:

Sign Up Today

Receive notifications on support alerts, critical issues,
fixes, and product releases.
*Required Fields
Highlighted fields are required
*Required Fields
Highlighted fields are required
By submitting this form, you give consent to receive notifications concerning support alerts, critical issues, important updates, fixes, and product releases via email. In addition, you consent to your business contact information being entered into our CRM solution that is hosted in the United States, but maintained consistent with applicable data protection laws.
**By clicking here, you give consent to be contacted for news, updates and other marketing purposes related to existing and future InterSystems products, offerings, and events.