Alert: SQL Query using “NOT %INLIST” fails to return results

InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.

This issue exists in the listed versions of the following products:

  • InterSystems IRIS® data platform
  • InterSystems IRIS for Health™
  • HealthShare® Health Connect

As well as:

  • Other InterSystems products based on the above products.

Impacted versions:

  • 2021.1.3, 2021.1.4
  • 2022.1.3, 2022.1.4
  • 2023.1.0, 2023.1.1, 2023.1.2, 2023.1.3
  • 2024.1.0

Only queries with the following conditions could return wrong results:

  • The WHERE clause contains a NOT %INLIST
  • There is a NULL value in the list

The correction for this defect is identified as DP-430793 and will be included in all future product releases beginning with: 2022.1.5, 2023.1.4, and 2024.1.267.2. It is also available via ad hoc distribution.
If you have any questions regarding this alert, please contact the Worldwide Response Center.

Sign Up Today

Receive notifications on support alerts, critical issues,
fixes, and product releases.
*Required Fields
Highlighted fields are required
*Required Fields
Highlighted fields are required
By submitting this form, you give consent to receive notifications concerning support alerts, critical issues, important updates, fixes, and product releases via email. In addition, you consent to your business contact information being entered into our CRM solution that is hosted in the United States, but maintained consistent with applicable data protection laws.
**By clicking here, you give consent to be contacted for news, updates and other marketing purposes related to existing and future InterSystems products, offerings, and events.