Skip to content
Search to learn about InterSystems products and solutions, career opportunities, and more.

Alert: Data Integrity Issues with the FHIR Resource Repository

June 4, 2020 – Alert: Data Integrity Issues with the FHIR Resource Repository

InterSystems has corrected a defect that can cause FHIR searches to return incomplete results. The defect manifests because a FHIR update interaction deletes an incorrect resource from the search index. Although the data still exists in the repository, subsequent searches may return incomplete results due to the missing entry in that index.

This defect affects InterSystems IRIS for Health 2020.1 and HealthShare Unified Care Record 2020.1. (In HealthShare, this defect only affects FHIR resources at the ODS. CDA documents and SDA are not affected; data displayed in the Clinical Viewer or retrieved by APIs other than the FHIR APIs are also not affected. For more details on how this defect affects HealthShare products, please see Advisory: Potential Data Integrity Issue with HealthShare FHIR Resource Searches against the FHIR Repository.)

InterSystems recommends that any customers using the FHIR Resource Repository on the affected version update their installations to the new distribution listed below. This distribution also contains a utility to repair the search index by restoring entries that were erroneously deleted. For more information on how to use that utility, please see the technical addendum to this document, Addendum For IF_766, available in the ‘Docs’ section of the WRC Distribution page.

The correction for this defect is identified as IF-766 and will be included in all future product releases. An updated distribution of InterSystems IRIS for Health has been posted for download. The original distribution without the correction was build 2020.1.0.215.0. The new distribution containing the correction is build 2020.1.0.217.1.

If you have any questions regarding this alert, please contact the Worldwide Response Center.

Latest Alerts & Advisories

Aug 15, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
Jul 24, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
Jun 24, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
May 30, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
Apr 30, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Apr 08, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
Mar 19, 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
Feb 27, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
Feb 01, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.

Sign Up Today

Receive notifications on support alerts, critical issues,
fixes, and product releases.
*Required Fields
Highlighted fields are required
*Required Fields
Highlighted fields are required
By submitting this form, you give consent to receive notifications concerning support alerts, critical issues, important updates, fixes, and product releases via email. In addition, you consent to your business contact information being entered into our CRM solution that is hosted in the United States, but maintained consistent with applicable data protection laws.
**By clicking here, you give consent to be contacted for news, updates and other marketing purposes related to existing and future InterSystems products, offerings, and events.