Advisory: Non-Unique Aggregation Keys Can Cause Key Collisions on Pure Query Edge Gateways

This problem affects the following products:

  • HealthShare Unified Care Record®, all versions up to and including 2024.2
    • 15.03
    • 2018.1
    • 2019.1
    • 2019.2
    • 2020.1
    • 2020.2
    • 2021.1
    • 2021.2
    • 2022.1
    • 2022.2
    • 2023.1
    • 2023.2
    • 2024.1
    • 2024.2

Requirements:

  • Using Pure Query Edge Gateway
  • More than one Pure Query Edge Gateway hosted in a single Unified Care Record instance

When two Pure Query Edge Gateways are deployed on a single instance, different data can be stored using the same aggregation key. This results in a data overlay, which can cause unexpected data to be returned to the Clinical Viewer.

The correction for this defect is identified as HSDD-2188, which will be included in all future product releases. It is also available via ad hoc change file (patch) or full kit distribution by contacting the Worldwide Response Center (WRC).

RELATED TOPICS

Latest Alerts & Advisories

21 oct. 2026
Advisory ID Products Affected Risk Category & Score Explicit Requirements DP-456155 All existing InterSystems interoperability products and solutions that use browser-based XSLT, including:
08 oct. 2026
We’re excited to introduce the new InterSystems Software Distribution Platform, available beginning October 8 at downloads.intersystems.com.
11 sept. 2026
This problem affects all versions of Unified Care Record and Information Exchange prior to 2026.2.
22 juil. 2026
The 2026.2 release of InterSystems IRIS® data platform, InterSystems IRIS® for Health™, and HealthShare® Health Connect is now Generally Available (GA). This is a Continuous Delivery (CD) release.
22 juil. 2026
This problem affects the following products:
22 juil. 2026
This problem affects the following products:

Passez à l'étape suivante

Nous serions ravis d'échanger avec vous. Remplissez les champs suivants et nous vous recontacterons.
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
** En cochant cette case, vous consentez à recevoir des actualités, des mises à jour et toute autre information à objectif marketing liés aux produits et événements actuels et futurs d'InterSystems. En outre, vous consentez à ce que vos coordonnées professionnelles soient saisies dans notre solution CRM hébergée aux États-Unis, mais conservées conformément aux lois applicables en matière de protection des données.