Skip to content
Effectuez une recherche pour en savoir plus sur les produits et solutions InterSystems, les offres d'emploi, etc.

Advisory: Missing Globals with Mirror Database Download

Summary

Advisory ID
Product & Versions Affected
Risk Category & ScoreExplicit Requirements
DP-444543
  • InterSystems IRIS® data platform
  • InterSystems IRIS® for Health
  • HealthShare® Health Connect
  • Versions 2025.1.0, 2025.1.1 and 2025.2
Operational: Medium Risk
Occurs only when using the Mirror Database Download feature with databases containing %SYS, %IRIS*, %odd, %nls*, %csp*, or other globals listed in the advisory.

Issue

In InterSystems IRIS, InterSystems IRIS for Health, and HealthShare Health Connect, versions 2025.1.1 and 2025.2.0, the new “ Mirror Database Download” functionality does not include certain globals. This is limited to the rare case when a mirrored database includes system global names that do not typically occur in mirrored databases. When using this feature, mirrored databases that contain the following globals will be incomplete:

  • %IRIS*
  • %ISC.*
  • %MV*
  • %SYS
  • %csp*
  • %iKnow
  • %nls*
  • %odd*
  • %sqlcq
  • %tercap
  • CacheTemp*
  • IRIS.* (except IRIS.Msg and IRIS.MsgNames)
  • ISC.* (except ISC.Src.Jrn)
  • mtemp*

Impact

This is a silent completeness issue: the mirrored database download appears successful but omits the above globals.

This issue affects versions 2025.1.0, 2025.1.1 and 2025.2.0 of the following products:

  • InterSystems IRIS
  • InterSystems IRIS for Health
  • HealthShare Health Connect

This issue only affects the new “ Mirror Database Download” feature. All existing mirroring features are fully operational and performing as expected. Using a manual restore to populate the mirror database (which was the default procedure prior to the release of this feature) is a simple workaround.

Resolution

This issue has been corrected in versions 2025.1.2 and 2025.3.0 of the products.

  • 2025.1.2 is scheduled for availability on October 22, 2025.
  • 2025.3.0 is scheduled for availability on November 19, 2025.
  • In the interim, customers who require the correction prior to these releases may request an ad hoc distribution for the fix (DP-444574) through the Worldwide Response Center.

If you need to populate a mirrored database containing any of the globals listed above, copy the globals from one mirror member to another either using traditional backup/restore strategies or by manually copying the IRIS.DAT database.

For More Information

If you have questions or need assistance, please contact the InterSystems Worldwide Response Center (WRC).

Latest Alerts & Advisories

22 Jul 2026
The 2026.2 release of InterSystems IRIS® data platform, InterSystems IRIS® for Health™, and HealthShare® Health Connect is now Generally Available (GA). This is a Continuous Delivery (CD) release.
17 Jul 2026
Primary impact is in lost time in attempting administrative activities through the GUI and in trying to identify what is causing the failure to load.
15 Apr 2026
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements IF-9262 InterSystems IRIS® for Health
14 Apr 2026
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements IF-9396 InterSystems IRIS® for Health
06 Apr 2026
Product & Versions Affected Risk Category & Score Explicit Requirements HSIEC-12800 InterSystems IRIS® for Health
25 Mar 2026
The 2026.1 release of InterSystems IRIS® data platform, InterSystems IRIS® for HealthTM, and HealthShare® Health Connect is now Generally Available (GA). This is an Extended Maintenance (EM) release.
18 Mar 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-449126 InterSystems IRIS® data platform
17 Mar 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-448888 Products:
26 Feb 2026
The problem affects the following versions of HealthShare Provider Directory:

Passez à l'étape suivante

Nous serions ravis d'échanger avec vous. Remplissez les champs suivants et nous vous recontacterons.
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
*Champs obligatoires
Veuillez remplir tous les champs obligatoires*
** En cochant cette case, vous consentez à recevoir des actualités, des mises à jour et toute autre information à objectif marketing liés aux produits et événements actuels et futurs d'InterSystems. En outre, vous consentez à ce que vos coordonnées professionnelles soient saisies dans notre solution CRM hébergée aux États-Unis, mais conservées conformément aux lois applicables en matière de protection des données.