Skip to content
Suchen Sie nach Produkten und Lösungen von InterSystems, Karrieremöglichkeiten und mehr.

Advisory: XDS PIX Patient Revise does not Merge Document Metadata Subscriptions (DSUB)

This problem affects the following products:

  • HealthShare Unified Care Record, all versions
  • HealthShare Health Connect, all versions
  • IRIS for Health, all versions

When PIX Patient Revise merge requests are received by InterSystems IHE components, patient identities and documents are successfully merged into the surviving patient record.
Document Metadata Subscriptions (DSUB) are not merged. As a result, the surviving record will not receive the DSUB from the subsumed patient record and the system will contain DSUB that do not reference a current patient record.

A clinical safety risk arises if the lost DSUB cause the system to fail to notify the intended recipients of clinical data.

A fix is not yet available for this issue and IHE does not provide guidance on how to handle DSUB after a Patient Revise.

This issue is identified as HSIEC-4944. Affected customers may contact InterSystems Worldwide Response Center (WRC) for assistance regarding this advisory.

Latest Alerts & Advisories

15 Aug 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
24 Jul 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
24 Jun 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
30 May 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
01 May 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
08 Apr 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
19 Mar 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
27 Feb 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
01 Feb 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.