Advisory: With Message Headers Enabled, Deletes and Resends Fail in Health Insight

This problem affects the following products:

  • HealthShare® Health Insight: 2022.2 • 2023.1 • 2023.2 • 2024.1

Requirements:

  • Health Insight customers that ingest MessageHeader streamlets

Health Insight 2022.2 added support for ingesting MessageHeader streamlets. For Health Insight systems fed from the Feeder Gateway (using AADBQ), deletes and resends of patients with an HSAA.MessageHeader entry will result in a Foreign Key Constraint error. The delete or resend of patient data to Health Insight will fail.

The correction for this defect is identified as HSHI-9361, which is included in version Health Insight 2024.2 and in all future product releases. It is also available for older versions via ad hoc change file (patch) or full kit distribution by contacting the Worldwide Response Center (WRC).

RELATED TOPICS

Latest Alerts & Advisories

Jul 24, 2025
InterSystems IRIS 2025.2 introduces the IRISSECURITY database, the new home for security data. Unlike IRISSYS, the previous home for security data, IRISSECURITY can be encrypted, which secures your sensitive data at rest. In a future version, IRISSECURITY will be mirrorable.
Jul 24, 2025
InterSystems is pleased to announce the General Availability (GA) of the 2025.2 release of InterSystems IRIS® data platform. This is a Continuous Delivery (CD) release. Please note that the GA versions of InterSystems IRIS for Health™ and HealthShare® Health Connect™ 2025.2 are currently withheld due to mirroring limitations introduced by security updates (details below).
Jun 11, 2025
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements DP-439649 Products:
May 21, 2025
This issue affects all versions of HealthShare®:
May 21, 2025
This problem affects the following products: