Skip to content
Telusuri untuk mempelajari tentang produk dan solusi InterSystems, peluang karier, dan banyak lagi.

Advisory: With Message Headers Enabled, Deletes and Resends Fail in Health Insight

This problem affects the following products:

  • HealthShare® Health Insight: 2022.2 • 2023.1 • 2023.2 • 2024.1

Requirements:

  • Health Insight customers that ingest MessageHeader streamlets

Health Insight 2022.2 added support for ingesting MessageHeader streamlets. For Health Insight systems fed from the Feeder Gateway (using AADBQ), deletes and resends of patients with an HSAA.MessageHeader entry will result in a Foreign Key Constraint error. The delete or resend of patient data to Health Insight will fail.

The correction for this defect is identified as HSHI-9361, which is included in version Health Insight 2024.2 and in all future product releases. It is also available for older versions via ad hoc change file (patch) or full kit distribution by contacting the Worldwide Response Center (WRC).

RELATED TOPICS

Latest Alerts & Advisories

16 April, 2026
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements IF-9262 InterSystems IRIS® for Health
15 April, 2026
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements IF-9396 InterSystems IRIS® for Health
06 April, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements HSIEC-12800 InterSystems IRIS® for Health
26 Maret, 2026
The 2026.1 release of InterSystems IRIS® data platform, InterSystems IRIS® for HealthTM, and HealthShare® Health Connect is now Generally Available (GA). This is an Extended Maintenance (EM) release.
18 Maret, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-449126 InterSystems IRIS® data platform
17 Maret, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-448888 Products:
27 Februari, 2026
The problem affects the following versions of HealthShare Provider Directory: