Skip to content
Suchen Sie nach Produkten und Lösungen von InterSystems, Karrieremöglichkeiten und mehr.

Alert: Possible Data Integrity Issues with Online Backup of Large Databases

May 20, 2020 – Alert: Possible Data Integrity Issues with Online Backup of Large Databases

InterSystems has corrected two defects that affect online backup of very large databases. Backups taken via external methods, such as snapshots or direct file copies, are not affected. These defects exist in all released versions of all InterSystems products.

The first defect only affects databases with more than 231 blocks. It results in a degraded database after restoring from an online backup. For example, databases that have a block size of 8 KB (the default) are only affected if they are larger than 16 TB. The correction for this defect is identified as RJF437.

The second defect affects databases that have a block size of 8 KB and that are larger than ~29 TB. With this defect, the online backup fails due to an inaccurate <DATABASE> error; this results in a backup that cannot be restored. The correction for this defect is identified as RJF438. Note that this defect also affects databases that have block sizes smaller than 8 KB.

The corrections for these defects will be included in all future product releases. They are also available by requesting an Ad hoc distribution from the WRC.

If you have any questions regarding this alert, please contact the Worldwide Response Center.

Latest Alerts & Advisories

15 Aug 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
24 Jul 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
24 Jun 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
30 May 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
01 May 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
08 Apr 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
19 Mar 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
27 Feb 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
01 Feb 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.