Advisory: XDS PIX Patient Revise does not Merge Document Metadata Subscriptions (DSUB)

This problem affects the following products:

  • HealthShare Unified Care Record, all versions
  • HealthShare Health Connect, all versions
  • IRIS for Health, all versions

When PIX Patient Revise merge requests are received by InterSystems IHE components, patient identities and documents are successfully merged into the surviving patient record.

Document Metadata Subscriptions (DSUB) are not merged. As a result, the surviving record will not receive the DSUB from the subsumed patient record and the system will contain DSUB that do not reference a current patient record.

A clinical safety risk arises if the lost DSUB cause the system to fail to notify the intended recipients of clinical data.

A fix is not yet available for this issue and IHE does not provide guidance on how to handle DSUB after a Patient Revise.

This issue is identified as HSIEC-4944. Affected customers may contact InterSystems Worldwide Response Center (WRC) for assistance regarding this advisory.

Latest Alerts & Advisories

07 Oct 2025
Risk Category & Score Explicit Requirements DP-442892 InterSystems IRIS® data platform InterSystems IRIS® for Health HealthShare® Health Connect versions 2023.3.0, 2024.1.0 – 2024.1.3, 2024.2.0, 2024.3.0, and 2025.1.0 HealthShare® Unified Care Record versions 2024.2 and 2025.1 Wrong Results: High Risk Specific use of OUTER JOIN when the inner leg has an index on the join fields In InterSystems IRIS versions 2023.3.0, 2024.1.0 – 2024.1.3, 2024.2.0, 2024.3.0, and 2025.1.0, for queries that use an OUTER JOIN and where InterSystems IRIS performs parallel execution, the query may silently return wrong results.
07 Oct 2025
Risk Category & Score Explicit Requirements HSHC-5268 HealthShare® Health Connect and InterSystems IRIS® for Health versions 2025.1.1 Functional: Medium Risk Occurs when performing SDA3 -> FHIR transformations involving the Encounter resource.
07 Oct 2025
Risk Category & Score Explicit Requirements DP-443396 InterSystems IRIS® data platform InterSystems IRIS® for Health HealthShare® Health Connect versions 2024.1.0 – 2024.1.4, 2024.2.0, 2024.3.0, and 2025.1.0, and 2025.1.1 HealthShare® Unified Care Record versions 2024.2 and 2025.1 Wrong Results: Low Risk Using Common Table Expressions in Dynamic SQL
30 Sep 2025
In InterSystems IRIS, InterSystems IRIS for Health, and HealthShare Health Connect, versions 2025.1.1 and 2025.2.0, the new “ Mirror Database Download” functionality does not include certain globals.
24 Sep 2025
Risk Category & Score Explicit Requirements DP-444551 InterSystems IRIS® data platform InterSystems IRIS® for Health HealthShare® Health Connect versions 2025.1.0, 2025.1.1, and 2025.2
03 Sep 2025
Risk Category & Score Explicit Requirements DP-442440 InterSystems IRIS ® data platform 2025.1.1.308.0 InterSystems IRIS for Health HealthShare® Health Connect Operational:
23 Jul 2025
InterSystems IRIS 2025.2 introduces the IRISSECURITY database, the new home for security data. Unlike IRISSYS, the previous home for security data, IRISSECURITY can be encrypted, which secures your sensitive data at rest. In a future version, IRISSECURITY will be mirrorable.
23 Jul 2025
InterSystems is pleased to announce the General Availability (GA) of the 2025.2 release of InterSystems IRIS® data platform. This is a Continuous Delivery (CD) release. Please note that the GA versions of InterSystems IRIS for Health™ and HealthShare® Health Connect™ 2025.2 are currently withheld due to mirroring limitations introduced by security updates (details below).
10 Jun 2025
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements DP-439649 Products:
20 May 2025
This issue affects all versions of HealthShare®: