Advisory: Users Unable to Log in After Upgrade Due to Missing Index

This problem affects the following products:

  • HealthShare Unified Care Record:  2021.2, 2022.1, 2022.2, 2023.1

In version 2021.2 of Unified Care Record, a new property was added to the user/clinician registry. After upgrading to an affected version, users may be unable to log into the system post-upgrade due to a missing index on the new property. A manual re-indexing step was added to the upgrade instructions for those versions after-the-fact.

The defect has been corrected in version 2023.2, and the relevant indices are now automatically rebuilt as part of the upgrade process.

For customers upgrading to an affected version of HealthShare, the workaround is to manually rebuild the indices after the Registry upgrade is complete by running the following command in terminal in the Registry namespace:

set status=##class(HS.Registry.Person.UserLoginID).%BuildIndices()

write status

There is no ad hoc patch associated with this advisory.

If you have any questions regarding this issue, please contact InterSystems Worldwide Response Center (WRC) for assistance and reference HSIEO-6028.

RELATED TOPICS

Latest Alerts & Advisories

16 April, 2026
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements IF-9262 InterSystems IRIS® for Health
15 April, 2026
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements IF-9396 InterSystems IRIS® for Health
06 April, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements HSIEC-12800 InterSystems IRIS® for Health
26 Maret, 2026
The 2026.1 release of InterSystems IRIS® data platform, InterSystems IRIS® for HealthTM, and HealthShare® Health Connect is now Generally Available (GA). This is an Extended Maintenance (EM) release.
18 Maret, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-449126 InterSystems IRIS® data platform
17 Maret, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-448888 Products:
27 Februari, 2026
The problem affects the following versions of HealthShare Provider Directory: