Advisory: Production Start May Fail Due to Unnecessary Recreation of OAUTH2 Client Configurations

This problem affects the following products:

  • HealthShare Unified Care Record: 2022.2 only

A defect in the HS 2022.2 release caused public OAuth 2.0 client configuration to be recreated at the time of Production Start even if the configuration was correct and should not have been recreated.

In some deployments, where a load balancer is configured, the defect caused a Production Start to fail if the load balancer happened to change the routing of the OAuth 2.0 configuration request to a different instance than the one on which the Production was being started.

A short-term workaround is available for customers until they are able to apply the long-term correction in their environment. The workaround for the Production Start failure is to temporarily reconfigure the load balancer to only point to one instance until the Production has been started. After that, the load balancer can be reverted to its typical state.

This has been corrected as of version 2023.1.

The long-term correction for this defect is identified as HSIEO-7278 which will be included in all future product releases. It is also available via ad hoc change file (patch) or full kit distribution by contacting the Worldwide Response Center (WRC).

RELATED TOPICS

Latest Alerts & Advisories

16 April, 2026
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements IF-9262 InterSystems IRIS® for Health
15 April, 2026
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements IF-9396 InterSystems IRIS® for Health
06 April, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements HSIEC-12800 InterSystems IRIS® for Health
26 Maret, 2026
The 2026.1 release of InterSystems IRIS® data platform, InterSystems IRIS® for HealthTM, and HealthShare® Health Connect is now Generally Available (GA). This is an Extended Maintenance (EM) release.
18 Maret, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-449126 InterSystems IRIS® data platform
17 Maret, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-448888 Products:
27 Februari, 2026
The problem affects the following versions of HealthShare Provider Directory: