Skip to content
Telusuri untuk mempelajari tentang produk dan solusi InterSystems, peluang karier, dan banyak lagi.

Advisory: Backup Mirror Member Cannot Communicate When Only Secure Communication Is Allowed

This problem affects the following product:

  • HealthShare Unified Care Record: all mirrored versions prior to 2022.2

With HealthShare 2022.2, the HealthShare Mirror Agent Monitor was redesigned. In versions prior to that redesign, a defect will cause a failure of Mirror Agent Monitor communication between the backup and primary mirror members if all unsecure HTTP communication is disabled, meaning that only secure HTTPS is available. If the backup member fails to communicate with the primary, the backup may not be able to take over as primary in the event of a failover.

The defect is caused by an improper value lookup by the backup member which results in an error. The value lookup will always fail on versions prior to 2022.2, but if HTTP communication is enabled, then the value lookup falls back to a different mechanism that does not fail.

All customers are discouraged from using unsecure HTTP communication whenever possible.

An ad hoc patch to correct the issue is available for older versions. Please contact the Worldwide Response Center (WRC) and refer to HSIEO-7727.

RELATED TOPICS

Latest Alerts & Advisories

10 Oktober, 2025
This alert supersedes the version issued on October 7, 2025. The original alert listed incorrect affected and fixed versions.
07 Oktober, 2025
Risk Category & Score Explicit Requirements HSHC-5268 HealthShare® Health Connect and InterSystems IRIS® for Health versions 2025.1.1 Functional: Medium Risk Occurs when performing SDA3 -> FHIR transformations involving the Encounter resource.
07 Oktober, 2025
Risk Category & Score Explicit Requirements DP-443396 InterSystems IRIS® data platform InterSystems IRIS® for Health HealthShare® Health Connect versions 2024.1.0 – 2024.1.4, 2024.2.0, 2024.3.0, and 2025.1.0, and 2025.1.1 HealthShare® Unified Care Record versions 2024.2 and 2025.1 Wrong Results: Low Risk Using Common Table Expressions in Dynamic SQL
07 Oktober, 2025
This alert has been corrected - please see: October 10 - Correction Notice: Updated Alert for DP-442892
30 September, 2025
In InterSystems IRIS, InterSystems IRIS for Health, and HealthShare Health Connect, versions 2025.1.1 and 2025.2.0, the new “ Mirror Database Download” functionality does not include certain globals.
24 September, 2025
Risk Category & Score Explicit Requirements DP-444551 InterSystems IRIS® data platform InterSystems IRIS® for Health HealthShare® Health Connect versions 2025.1.0, 2025.1.1, and 2025.2
03 September, 2025
Risk Category & Score Explicit Requirements DP-442440 InterSystems IRIS ® data platform 2025.1.1.308.0 InterSystems IRIS for Health HealthShare® Health Connect Operational:
24 Juli, 2025
InterSystems IRIS 2025.2 introduces the IRISSECURITY database, the new home for security data. Unlike IRISSYS, the previous home for security data, IRISSECURITY can be encrypted, which secures your sensitive data at rest. In a future version, IRISSECURITY will be mirrorable.
24 Juli, 2025
InterSystems is pleased to announce the General Availability (GA) of the 2025.2 release of InterSystems IRIS® data platform. This is a Continuous Delivery (CD) release. Please note that the GA versions of InterSystems IRIS for Health™ and HealthShare® Health Connect™ 2025.2 are currently withheld due to mirroring limitations introduced by security updates (details below).