Advisory: Backup Mirror Member Cannot Communicate When Only Secure Communication Is Allowed

This problem affects the following product:

  • HealthShare Unified Care Record: all mirrored versions prior to 2022.2

With HealthShare 2022.2, the HealthShare Mirror Agent Monitor was redesigned. In versions prior to that redesign, a defect will cause a failure of Mirror Agent Monitor communication between the backup and primary mirror members if all unsecure HTTP communication is disabled, meaning that only secure HTTPS is available. If the backup member fails to communicate with the primary, the backup may not be able to take over as primary in the event of a failover.

The defect is caused by an improper value lookup by the backup member which results in an error. The value lookup will always fail on versions prior to 2022.2, but if HTTP communication is enabled, then the value lookup falls back to a different mechanism that does not fail.

All customers are discouraged from using unsecure HTTP communication whenever possible.

An ad hoc patch to correct the issue is available for older versions. Please contact the Worldwide Response Center (WRC) and refer to HSIEO-7727.

RELATED TOPICS

Latest Alerts & Advisories

03 September, 2025
Risk Category & Score Explicit Requirements DP-442440 InterSystems IRIS ® data platform 2025.1.1.308.0 InterSystems IRIS for Health HealthShare® Health Connect Operational:
24 Juli, 2025
InterSystems IRIS 2025.2 introduces the IRISSECURITY database, the new home for security data. Unlike IRISSYS, the previous home for security data, IRISSECURITY can be encrypted, which secures your sensitive data at rest. In a future version, IRISSECURITY will be mirrorable.
24 Juli, 2025
InterSystems is pleased to announce the General Availability (GA) of the 2025.2 release of InterSystems IRIS® data platform. This is a Continuous Delivery (CD) release. Please note that the GA versions of InterSystems IRIS for Health™ and HealthShare® Health Connect™ 2025.2 are currently withheld due to mirroring limitations introduced by security updates (details below).
11 Juni, 2025
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements DP-439649 Products:
21 Mei, 2025
This issue affects all versions of HealthShare®:
21 Mei, 2025
This problem affects the following products: