Skip to content
Telusuri untuk mempelajari tentang produk dan solusi InterSystems, peluang karier, dan banyak lagi.

Advisory: Health Insight Feeder Gateway Aggregation Cache Grows over Time

This problem affects the following products:

  • HealthShare Health Insight, all versions up to and including 2021.2

InterSystems has detected a minor system stability concern in Health Insight. The system can stop if server disk space becomes full due to a cache slowly filling over time.

The issue is within the aggregation cache of the Health Insight Feeder Gateway which aggregates records across Edge Gateways into a single patient record for ingestion into Health Insight. Streamlets are stored in the aggregation cache during this process and the data should be purged after the completion of each session. However the purge may fail, leaving the data in the cache.

The data is purged if the Feeder Gateway is reset.

A set of fixes are available for this issue and will be included in all future versions of HealthShare, beginning with HealthShare Unified Care Record 2022.1.

Additional Information

Routine monitoring of disk space helps to reduce the likelihood of encountering system stability issues. For information on monitoring disk space, see the HealthShare Monitoring and Operations Guide.

Reference Information

The corrections for this defect are available via Ad hoc distribution from the InterSystems Worldwide Response Center (WRC). They are identified as HSIEC-5574 and HSIEC-5586.

RELATED TOPICS

Latest Alerts & Advisories

21 October, 2026
Advisory ID Products Affected Risk Category & Score Explicit Requirements DP-456155 All existing InterSystems interoperability products and solutions that use browser-based XSLT, including:
09 October, 2026
We’re excited to introduce the new InterSystems Software Distribution Platform, available beginning October 8 at downloads.intersystems.com.
12 September, 2026
This problem affects all versions of Unified Care Record and Information Exchange prior to 2026.2.
23 July, 2026
The 2026.2 release of InterSystems IRIS® data platform, InterSystems IRIS® for Health™, and HealthShare® Health Connect is now Generally Available (GA). This is a Continuous Delivery (CD) release.
22 July, 2026
There are 6 alerts in the HealthShare HS2026-01 Alert communication. Alert Summaries are shown in the table below. Alert details are contained in the PDF document: HS-2026-01-Alert-Document
22 July, 2026
There are 4 alerts in the HealthShare HS2026-02 Alert communication. Alert Summaries are shown in the table below. Alert details are contained in the PDF document: HS-2026-02-Alert-Document
22 July, 2026
This problem affects the following products: