Advisory: Resource Exhaustion Using XCPD/XCA

This problem affects the following products:

  • All versions of HealthShare Unified Care Record® and Information Exchange prior to 2025.2

Requirements:

  • IHE XCA

The XCPD Responding Gateway in the XCA workflow is synchronous but has no timeout implemented, so a sufficiently high request rate for a sustained period of time can result in an ever-increasing queue of synchronous requests, each with their own process.

Once a threshold of processes is reached, the server can reach resource exhaustion, resulting in a crash.

The correction for this defect is identified as HSIEC-11400, which is included in version 2025.2 and in all future product releases. It is also available for older versions via ad hoc change file (patch) or full kit distribution by contacting the Worldwide Response Center (WRC).

Latest Alerts & Advisories

18 March, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-449126 InterSystems IRIS® data platform
17 March, 2026
Product & Versions Affected Risk Category & Score Explicit Requirements DP-448888 Products:
27 February, 2026
The problem affects the following versions of HealthShare Provider Directory:
11 February, 2026
This problem affects all versions the following products prior to 2025.2: