Summary

Advisory ID
Product & Versions Affected
Risk Category & ScoreExplicit Requirements
DP-444543
  • InterSystems IRIS® data platform
  • InterSystems IRIS® for Health
  • HealthShare® Health Connect
  • Versions 2025.1.0, 2025.1.1 and 2025.2
Operational: Medium Risk
Occurs only when using the Mirror Database Download feature with databases containing %SYS, %IRIS*, %odd, %nls*, %csp*, or other globals listed in the advisory.

Issue

In InterSystems IRIS, InterSystems IRIS for Health, and HealthShare Health Connect, versions 2025.1.1 and 2025.2.0, the new “ Mirror Database Download” functionality does not include certain globals. This is limited to the rare case when a mirrored database includes system global names that do not typically occur in mirrored databases. When using this feature, mirrored databases that contain the following globals will be incomplete:

  • %IRIS*
  • %ISC.*
  • %MV*
  • %SYS
  • %csp*
  • %iKnow
  • %nls*
  • %odd*
  • %sqlcq
  • %tercap
  • CacheTemp*
  • IRIS.* (except IRIS.Msg and IRIS.MsgNames)
  • ISC.* (except ISC.Src.Jrn)
  • mtemp*

Impact

This is a silent completeness issue: the mirrored database download appears successful but omits the above globals.

This issue affects versions 2025.1.0, 2025.1.1 and 2025.2.0 of the following products:

  • InterSystems IRIS
  • InterSystems IRIS for Health
  • HealthShare Health Connect

This issue only affects the new “ Mirror Database Download” feature. All existing mirroring features are fully operational and performing as expected. Using a manual restore to populate the mirror database (which was the default procedure prior to the release of this feature) is a simple workaround.

Resolution

This issue has been corrected in versions 2025.1.2 and 2025.3.0 of the products.

  • 2025.1.2 is scheduled for availability on October 22, 2025.
  • 2025.3.0 is scheduled for availability on November 19, 2025.
  • In the interim, customers who require the correction prior to these releases may request an ad hoc distribution for the fix (DP-444574) through the Worldwide Response Center.

If you need to populate a mirrored database containing any of the globals listed above, copy the globals from one mirror member to another either using traditional backup/restore strategies or by manually copying the IRIS.DAT database.

For More Information

If you have questions or need assistance, please contact the InterSystems Worldwide Response Center (WRC).

Latest Alerts & Advisories

24 September, 2025
Risk Category & Score Explicit Requirements DP-444551 InterSystems IRIS® data platform InterSystems IRIS® for Health HealthShare® Health Connect versions 2025.1.0, 2025.1.1, and 2025.2
03 September, 2025
Risk Category & Score Explicit Requirements DP-442440 InterSystems IRIS ® data platform 2025.1.1.308.0 InterSystems IRIS for Health HealthShare® Health Connect Operational:
24 July, 2025
InterSystems IRIS 2025.2 introduces the IRISSECURITY database, the new home for security data. Unlike IRISSYS, the previous home for security data, IRISSECURITY can be encrypted, which secures your sensitive data at rest. In a future version, IRISSECURITY will be mirrorable.
24 July, 2025
InterSystems is pleased to announce the General Availability (GA) of the 2025.2 release of InterSystems IRIS® data platform. This is a Continuous Delivery (CD) release. Please note that the GA versions of InterSystems IRIS for Health™ and HealthShare® Health Connect™ 2025.2 are currently withheld due to mirroring limitations introduced by security updates (details below).
11 June, 2025
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements DP-439649 Products:
21 May, 2025
This issue affects all versions of HealthShare®:
21 May, 2025
This problem affects the following products: