Advisory: Orphaned Data after XDS.b Query and Retrieve Requests Can Cause Storage Issues

This problem affects the following products:

  • All versions of Unified Care Record

Requirements:

  • IHE XDS.b
  • Document Attachments
  • Either of the following non-default settings selected in the HS.IHE.XDSb.Repository.Services business service:
    • DeleteProvideAndRegisterAttachments
    • DeleteRetrieveAttachments

Customers who process XDS.b documents with attachments and have selected either the DeleteProvideAndRegisterAttachments or the DeleteRetrieveAttachments setting are affected by this issue. These settings are deselected by default.

Document attachments are typically purged on a regular basis along with interoperability messages. These settings were intended to purge XDS.b attachments immediately after processing. Contrary to that intention, these settings instead caused only references to the attachment data to be removed, thus leaving behind orphaned document stream data that is not removed in the message purge.

The operational risk is that growth of the orphaned data might cause storage exhaustion.

The corrections for this defect are identified as:

  • HSDD-5197
  • HSDD-6249
  • HSDD-6260

They are included in version 2026.1 of HealthShare and all future product releases. They are also available for older versions via ad hoc change file (patch) or full kit distribution by contacting the Worldwide Response Center (WRC). If you require assistance in removing orphaned attachment data, contact the WRC.

Latest Alerts & Advisories

okt. 21, 2026
Advisory ID Products Affected Risk Category & Score Explicit Requirements DP-456155 All existing InterSystems interoperability products and solutions that use browser-based XSLT, including:
okt. 08, 2026
We’re excited to introduce the new InterSystems Software Distribution Platform, available beginning October 8 at downloads.intersystems.com.
sep. 11, 2026
This problem affects all versions of Unified Care Record and Information Exchange prior to 2026.2.
juli 22, 2026
The 2026.2 release of InterSystems IRIS® data platform, InterSystems IRIS® for Health™, and HealthShare® Health Connect is now Generally Available (GA). This is a Continuous Delivery (CD) release.
juli 22, 2026
This problem affects the following products:
juli 22, 2026
This problem affects the following products:

Sign Up Today

Receive notifications on support alerts, critical issues,
fixes, and product releases.
*Required Fields
Highlighted fields are required
*Required Fields
Highlighted fields are required
By submitting this form, you give consent to receive notifications concerning support alerts, critical issues, important updates, fixes, and product releases via email. In addition, you consent to your business contact information being entered into our CRM solution that is hosted in the United States, but maintained consistent with applicable data protection laws.
**By clicking here, you give consent to be contacted for news, updates and other marketing purposes related to existing and future InterSystems products, offerings, and events.