Skip to content
Keressen, hogy többet megtudjon az InterSystems termékeiről és megoldásairól, karrierlehetőségekről és még sok másról.

Advisory: ODS Audit Aggregation may Fail when Sending Audit Data to Audit Repository

This problem affects the following products:

  • HealthShare Unified Care Record  ̶  This may occur in “mixed-version” deployments of Unified Care Record when the Registry or Audit Repository is on an older version (likely 2019.1) and the ODS has been upgraded to a newer version such as 2021.2.

The issue is triggered by a backward incompatibility in Audit Aggregation between different versions of Unified Care Record. The impact of the issue is that instances that are not on the same version as the Audit Repository may not be sending audit data to the Repository successfully.

If an instance is impacted by this issue, the queue of audit aggregation data will continue to build indefinitely until the issue is resolved. Specifically, the ^HS.AuditQueueSendErr global in the HSSYS namespace will continue to grow until the issue is resolved. An administrator can check whether or not their instance is failing to send audit data to the repository by checking the Task History of the following two tasks on the potentially affected instance:

  • ATNA HealthShare Event Aggregation Task
  • ATNA IRIS Event Aggregation Task

In addition, Audit Information related to patient queries, patient fetches, etc. will not be available for query on the Audit Repository.

Until the instance on the newer version is patched with HSIEO-6079, these tasks will continue to fail, and the ^HS.AuditQueueSendErr global in the HSSYS namespace will continue to grow.

Special Note: A small fraction of customers may have already requested ad hoc corrections with specific bug fixes or enhancements related to Audit Aggregation (for example, HSIEO-5985, HSIEO-2594, HSIEO-3336, HSIEO-4667, or HSIEO-3841). The application of HSIEO-6079 to the higher-versioned instance of ODS will not affect these customers negatively.

To resolve this issue, please request an adhoc patch for HSIEO-6079 from the Worldwide Response Center (WRC).

RELATED TOPICS

Latest Alerts & Advisories

Oct 07, 2025
Risk Category & Score Explicit Requirements DP-442892 InterSystems IRIS® data platform InterSystems IRIS® for Health HealthShare® Health Connect versions 2023.3.0, 2024.1.0 – 2024.1.3, 2024.2.0, 2024.3.0, and 2025.1.0 HealthShare® Unified Care Record versions 2024.2 and 2025.1 Wrong Results: High Risk Specific use of OUTER JOIN when the inner leg has an index on the join fields In InterSystems IRIS versions 2023.3.0, 2024.1.0 – 2024.1.3, 2024.2.0, 2024.3.0, and 2025.1.0, for queries that use an OUTER JOIN and where InterSystems IRIS performs parallel execution, the query may silently return wrong results.
Oct 07, 2025
Risk Category & Score Explicit Requirements DP-443396 InterSystems IRIS® data platform InterSystems IRIS® for Health HealthShare® Health Connect versions 2024.1.0 – 2024.1.4, 2024.2.0, 2024.3.0, and 2025.1.0, and 2025.1.1 HealthShare® Unified Care Record versions 2024.2 and 2025.1 Wrong Results: Low Risk Using Common Table Expressions in Dynamic SQL
Oct 07, 2025
Risk Category & Score Explicit Requirements HSHC-5268 HealthShare® Health Connect and InterSystems IRIS® for Health versions 2025.1.1 Functional: Medium Risk Occurs when performing SDA3 -> FHIR transformations involving the Encounter resource.
Sep 30, 2025
In InterSystems IRIS, InterSystems IRIS for Health, and HealthShare Health Connect, versions 2025.1.1 and 2025.2.0, the new “ Mirror Database Download” functionality does not include certain globals.
Sep 24, 2025
Risk Category & Score Explicit Requirements DP-444551 InterSystems IRIS® data platform InterSystems IRIS® for Health HealthShare® Health Connect versions 2025.1.0, 2025.1.1, and 2025.2
Sep 03, 2025
Risk Category & Score Explicit Requirements DP-442440 InterSystems IRIS ® data platform 2025.1.1.308.0 InterSystems IRIS for Health HealthShare® Health Connect Operational:
Jul 23, 2025
InterSystems IRIS 2025.2 introduces the IRISSECURITY database, the new home for security data. Unlike IRISSYS, the previous home for security data, IRISSECURITY can be encrypted, which secures your sensitive data at rest. In a future version, IRISSECURITY will be mirrorable.
Jul 23, 2025
InterSystems is pleased to announce the General Availability (GA) of the 2025.2 release of InterSystems IRIS® data platform. This is a Continuous Delivery (CD) release. Please note that the GA versions of InterSystems IRIS for Health™ and HealthShare® Health Connect™ 2025.2 are currently withheld due to mirroring limitations introduced by security updates (details below).
Jun 10, 2025
Advisory ID Product & Versions Affected Risk Category & Score Explicit Requirements DP-439649 Products:
May 20, 2025
This issue affects all versions of HealthShare®: