Skip to content
Keressen, hogy többet megtudjon az InterSystems termékeiről és megoldásairól, karrierlehetőségekről és még sok másról.

Alert: Possible Logical Data Integrity Issue after Crash

June 6, 2019 – Alert: Possible Logical Data Integrity Issue after Crash

InterSystems has corrected a defect that can result in application data integrity issues following an abnormal shutdown.

This problem exists for:

  • Caché and Ensemble 2018.1.2
  • HealthShare Health Connect (HSAP) 15.032 on Core version 2018.1.2
  • InterSystems IRIS Data Platform 2019.1
  • InterSystems IRIS for Health 2019.1
  • HealthShare Health Connect 2019.1

The defect breaks the journal sync guarantee that all updates in the journal buffer have been written to the journal file. The failure is silent: it does not generate an error message and there is no entry about it in any log file.

Specifically, an abnormal shutdown that occurs immediately after a journal sync may result in journal updates that cannot be recovered during the subsequent startup because they were never committed to disk in the journal file. An abnormal shutdown results from either:

  • A forced shutdown of the instance
  • An operating system shutdown or crash

The correction for this defect is identified as HYY2350. It will be included in all future product releases. It is also available via Ad hoc distribution from the InterSystems Worldwide Response Center (WRC).

If you have any questions regarding this alert, please contact the Worldwide Response Center.

Latest Alerts & Advisories

Aug 15, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
Jul 24, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
Jun 24, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
May 30, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Apr 08, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
Mar 19, 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
Feb 27, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
Feb 01, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.