Alert: Possible Data Integrity Issues after Adding Mirrored Database

April 2, 2020 – Alert: Possible Data Integrity Issues after Adding Mirrored Database

InterSystems has corrected a defect that can result in data integrity issues on systems using mirroring.

This defect affects:

  • All currently released versions of InterSystems IRIS and IRIS for Health, except 2020.1
  • Caché and Ensemble versions beginning with 2011.1.1
  • All HealthShare products based on the above Data Platforms versions

This defect is more likely to be encountered in IRIS and IRIS for Health 2019.4. It is highly unlikely to have occurred on deployed systems running any other version.

The issue can only occur in a situation that meets all of the following conditions:

  1. A database is removed from a mirror
  2. A database is added to the same mirror – this can be the same database or another one
  3. There is no journal switch between removing the first database and adding the second one.

If a system encounters the defect, then the current journal file will be intact on the primary system where the database was added, but a small subset of updates in that journal file will be missing from the newly added mirrored database on all other mirror members – both failover and async members. All updates from subsequent journal files are correctly dejournaled.

There is no way to definitively determine if the defect has been encountered, but you can use the DataCheck utility to confirm the consistency of a mirror set. For more information about DataCheck, see the “ Data Consistency On Multiple Systems” section of the Data Integrity Guide.

The correction for this defect is identified as HYY2390 and will be included in all future product releases. It is also available by requesting an Ad hoc distribution from the InterSystems Worldwide Response Center (WRC).

If you have any questions regarding this alert, please contact the Worldwide Response Center.

最新警报和通知

Aug 21, 2024
InterSystems 已修复了一个缺陷,在极少数情况下,该缺陷可能导致多卷数据库出现数据库损坏或 错误。只有被截断的数据库才存在风险。
Jun 03, 2024
从发布InterSystems IRIS®数据平台2022.3开始,InterSystems修改了许可证强制执行机制,以包括REST和SOAP请求。由于这种变化,在升级后,使用REST或SOAP的非处理器核数的许可证环境下,用户可能会遇到更高的许可证消耗。要确定此警报是否适用于您的InterSystems许可证,请按照下面链接的FAQ中的说明进行操作。
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Nov 14, 2023
There are 10 alerts in the HealthShare HS2023-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2023-02-Communication.
Jun 17, 2023
InterSystems 已纠正导致进程内存使用量增加的缺陷。
May 11, 2023
InterSystems已经解决了影响Caché、Ensemble、HealthShare、InterSystems IRIS、InterSystems IRIS for Health、HealthShare HealthConnect和TrakCare的安全漏洞。 这些漏洞影响到InterSystems所有版本的产品。
Apr 28, 2023
InterSystems 已修复了一个缺陷,该缺陷可能会导致使用 IBM POWER8 或更高版本的 POWER 处理器的 AIX 系统上的数据库和Journal日志文件损坏。只有在使用数据库或Journal日志加密时才会触发此缺陷。
Apr 11, 2023
InterSystems已修复一个缺陷,该缺陷在罕见情况下会导致ECP客户端不稳定。
Apr 06, 2023
InterSystems 已修复一个导致SQL查询返回不正确结果的缺陷。该缺陷存在于以下产品和基于这些产品的任何InterSystems产品中。