Skip to content
搜索以了解InterSystems产品和解决方案,职业机会等。

Alert: HS2021-03: Potential Data Integrity Issue with Mirror Dejournaling - HealthShare

March 23, 2021 – Alert: HS2021-03: Potential Data Integrity Issue with Mirror Dejournaling - HealthShare

InterSystems has corrected a defect that can cause data inconsistency issues on non-primary mirror members in extremely rare circumstances.

This problem exists for:

  • HealthShare Unified Care Record/Information Exchange, Health Insight, and Patient Index version 15.02 and newer
  • HealthShare Personal Community version 12.0 and newer
  • HealthShare Provider Directory 2019.2, 2020.1 and 2020.2
  • HealthShare Health Connect and HSAP versions that support mirroring.

If the defect occurs, it happens silently during normal operation on a mirrored system. The result of this defect is that a mirror member fails to dejournal a subset of journal records, which then leads to data inconsistency across mirror members.  This affects both failover and async members.  Although this defect is very unlikely to be encountered, InterSystems recommends that all customers using mirroring obtain the corrections and verify the consistency of mirrored databases with DataCheck.

InterSystems recommends that all customers using mirroring verify the consistency of mirrored databases with DataCheck.  If issues are found with the consistency of mirrored databases after running DataCheck, please contact the WRC.  InterSystems also recommends customers request an adhoc that contains: SML2898, HYY2434, and HYY2435 and apply it to your instances that use mirroring.

The correction for this defect is identified as HSIEO-4081 which includes SML2898, HYY2434, and HYY2435 will be included in all future product releases. It is also available via Ad hoc change file (patch) or full kit distribution from the Worldwide Response Center (WRC).

This post is part of the HealthShare HS2021-03 Alert communications process.  The same information was also distributed:

RELATED TOPICS

最新警报和通知

Aug 21, 2024
InterSystems 已修复了一个缺陷,在极少数情况下,该缺陷可能导致多卷数据库出现数据库损坏或 错误。只有被截断的数据库才存在风险。
Jun 03, 2024
从发布InterSystems IRIS®数据平台2022.3开始,InterSystems修改了许可证强制执行机制,以包括REST和SOAP请求。由于这种变化,在升级后,使用REST或SOAP的非处理器核数的许可证环境下,用户可能会遇到更高的许可证消耗。要确定此警报是否适用于您的InterSystems许可证,请按照下面链接的FAQ中的说明进行操作。
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Nov 14, 2023
There are 10 alerts in the HealthShare HS2023-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2023-02-Communication.
Jun 17, 2023
InterSystems 已纠正导致进程内存使用量增加的缺陷。
May 11, 2023
InterSystems已经解决了影响Caché、Ensemble、HealthShare、InterSystems IRIS、InterSystems IRIS for Health、HealthShare HealthConnect和TrakCare的安全漏洞。 这些漏洞影响到InterSystems所有版本的产品。
Apr 28, 2023
InterSystems 已修复了一个缺陷,该缺陷可能会导致使用 IBM POWER8 或更高版本的 POWER 处理器的 AIX 系统上的数据库和Journal日志文件损坏。只有在使用数据库或Journal日志加密时才会触发此缺陷。
Apr 11, 2023
InterSystems已修复一个缺陷,该缺陷在罕见情况下会导致ECP客户端不稳定。
Apr 06, 2023
InterSystems 已修复一个导致SQL查询返回不正确结果的缺陷。该缺陷存在于以下产品和基于这些产品的任何InterSystems产品中。