March 11, 2020 – Advisory: Incorrect HealthShare Mirror Upgrade Documentation could lead to Data Integrity issues

InterSystems has corrected a defect in the steps needed to upgrade a mirrored HealthShare environment.

This problem exists for:

  • All versions of HealthShare Information Exchange, Unified Care Record, Patient Index, Health Insight, or Personal Community that support mirroring prior to version 2019.2.

This does not affect any versions of Health Connect or IRIS for Health.

In previous versions, the HealthShare mirror upgrade procedure was written in a way that minimized system downtime. Specifically, the mirror upgrade instructions allowed customers to continue processing new data until after the backup mirror member was already successfully upgraded and running the new version. Due to changes in the data model between versions, the recommendation now is to stop processing new data immediately upon beginning the upgrade procedure.

If customers were to follow the previously documented mirror upgrade procedure, it could cause an issue where new data comes in using the data model from the previous version, but then gets mirrored to a backup member without going through the proper conversion steps.

For more information, please see the 2019.2 mirror upgrade documentation.

With each upgrade, it is important to review and follow the upgrade instructions included for the version. The new procedure of turning off data feeds at the beginning of the upgrade should be followed for all upgrades, including those to previous versions such as 2019.1 or 2018.1. The documentation for these version has been updated.

Customers upgrading their mirrored environments should NOT reference the documentation available with their current version. Instead, they should reference the HealthShare 2019.2 online documentation for the correct set of instructions, specifically the section titled Upgrading a Unified Care Record Mirror.

There are no code changes related to this Advisory and an Ad hoc is not required.

If you have any questions regarding this advisory, please contact the Worldwide Response Center (WRC).

RELATED TOPICS

最新警报和通知

Aug 21, 2024
InterSystems 已修复了一个缺陷,在极少数情况下,该缺陷可能导致多卷数据库出现数据库损坏或 错误。只有被截断的数据库才存在风险。
Jun 03, 2024
从发布InterSystems IRIS®数据平台2022.3开始,InterSystems修改了许可证强制执行机制,以包括REST和SOAP请求。由于这种变化,在升级后,使用REST或SOAP的非处理器核数的许可证环境下,用户可能会遇到更高的许可证消耗。要确定此警报是否适用于您的InterSystems许可证,请按照下面链接的FAQ中的说明进行操作。
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Nov 14, 2023
There are 10 alerts in the HealthShare HS2023-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2023-02-Communication.
Jun 17, 2023
InterSystems 已纠正导致进程内存使用量增加的缺陷。
May 11, 2023
InterSystems已经解决了影响Caché、Ensemble、HealthShare、InterSystems IRIS、InterSystems IRIS for Health、HealthShare HealthConnect和TrakCare的安全漏洞。 这些漏洞影响到InterSystems所有版本的产品。
Apr 28, 2023
InterSystems 已修复了一个缺陷,该缺陷可能会导致使用 IBM POWER8 或更高版本的 POWER 处理器的 AIX 系统上的数据库和Journal日志文件损坏。只有在使用数据库或Journal日志加密时才会触发此缺陷。
Apr 11, 2023
InterSystems已修复一个缺陷,该缺陷在罕见情况下会导致ECP客户端不稳定。
Apr 06, 2023
InterSystems 已修复一个导致SQL查询返回不正确结果的缺陷。该缺陷存在于以下产品和基于这些产品的任何InterSystems产品中。