Advisory: HL7, X12, ASTM and EDIFACT Message Processing

May 8, 2015 – Advisory: HL7, X12, ASTM and EDIFACT Message Processing

InterSystems has corrected a defect that causes errors when updating segmented virtual documents such as HL7, X12, ASTM and EDIFACT. The error is triggered by a specific sequence of operations, namely:

1)   Clone an existing message OR create a message using a class method of the form ImportFrom…

2)   Use the method GetSegmentAt to fetch an individual segment of the message.

These steps cause the segment to be incorrectly marked immutable; it cannot be changed. Attempts to modify the segment fail with the message “<ENS>ErrGeneralSegment is immutable”

DTL (Data Transformation Language) usage is not at risk from this defect unless the GetSegmentAt method is explicitly called in a custom code block.

This Advisory applies to Ensemble and HealthShare on all platforms. This defect only exists in versions 2015.1 and 2015.1.1.

The correction for this defect is identified as JGM282. It will be included in all future releases of Ensemble and HealthShare. The correction is also available via Ad Hoc distribution from InterSystems Worldwide Response Center (WRC). If you have any questions regarding this advisory, please contact the Worldwide Response Center

最新警报和通知

Aug 21, 2024
InterSystems 已修复了一个缺陷,在极少数情况下,该缺陷可能导致多卷数据库出现数据库损坏或 错误。只有被截断的数据库才存在风险。
Jun 03, 2024
从发布InterSystems IRIS®数据平台2022.3开始,InterSystems修改了许可证强制执行机制,以包括REST和SOAP请求。由于这种变化,在升级后,使用REST或SOAP的非处理器核数的许可证环境下,用户可能会遇到更高的许可证消耗。要确定此警报是否适用于您的InterSystems许可证,请按照下面链接的FAQ中的说明进行操作。
May 01, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Nov 14, 2023
There are 10 alerts in the HealthShare HS2023-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2023-02-Communication.
Jun 17, 2023
InterSystems 已纠正导致进程内存使用量增加的缺陷。
May 11, 2023
InterSystems已经解决了影响Caché、Ensemble、HealthShare、InterSystems IRIS、InterSystems IRIS for Health、HealthShare HealthConnect和TrakCare的安全漏洞。 这些漏洞影响到InterSystems所有版本的产品。
Apr 28, 2023
InterSystems 已修复了一个缺陷,该缺陷可能会导致使用 IBM POWER8 或更高版本的 POWER 处理器的 AIX 系统上的数据库和Journal日志文件损坏。只有在使用数据库或Journal日志加密时才会触发此缺陷。
Apr 11, 2023
InterSystems已修复一个缺陷,该缺陷在罕见情况下会导致ECP客户端不稳定。
Apr 06, 2023
InterSystems 已修复一个导致SQL查询返回不正确结果的缺陷。该缺陷存在于以下产品和基于这些产品的任何InterSystems产品中。