Advisory: FHIR Server unusable after upgrade to InterSystems IRIS for Health 2021.1

This problem affects the following products:

  • InterSystems IRIS for Health 2021.1

If an OnAfterRequest() method override for HS.FHIRServer.Storage.Json.Interactions has been configured, data posted to the FHIR Repository will not be queryable in subsequent GET requests. Customers may avoid the issue by calling ##super() at the end of their custom OnAfterRequest() code.
A permanent fix is available by requesting an ad hoc correction for IF-2800 from the Worldwide Response Center (WRC).

Latest Alerts & Advisories

Aug 15, 2024
InterSystems has corrected a defect that can cause database corruption or errors with multi-volume databases under extremely rare circumstances. Only databases that have been truncated are at risk.
Jul 24, 2024
There are four alerts in the HS2024-03 Alert Communication. A summary of each alert is shown below. Details for each alert are contained in the linked document.
Jun 24, 2024
Broadcom recently announced a problem that can cause data consistency errors in database applications. The Broadcom article is available here:
May 30, 2024
Beginning with the release of InterSystems IRIS® data platform 2022.3, InterSystems corrected the license enforcement mechanism to include REST and SOAP requests. Due to this change, environments with non-core-based licenses that use REST or SOAP may experience greater license utilization after upgrading. To determine if this advisory applies to your InterSystems license, follow the instructions in the FAQ linked below.
Apr 30, 2024
InterSystems has corrected an issue that can cause a small number of SQL queries to return incorrect results. See below for the specifics on impacted queries.
Apr 08, 2024
InterSystems has encountered a defect that causes some upgrades of HealthShare® Health Connect to fail. This only affects instances that are not licensed for the use of FHIR® and that have interoperability-enabled namespaces. Under these conditions, the upgrade fails with an error.
Mar 19, 2024
In evaluating an IBM Support notification, InterSystems has determined a potential impact for our customers. The notification in question is:
Feb 27, 2024
There is 1 alert in the HealthShare HS2024-limited Alert communication. An alert summary for the issue is shown is in the table below. Details for the alert are contained in the attached document: HS2024 Limited Communication.
Feb 01, 2024
There are 2 alerts in the HealthShare HS2024-02 Alert communication. An alert summary for each issue is shown is in the table below. Details for each alert are contained in the attached document: HS2024-02-Communication.